CARIN-RDI consists of remote module (RT) and control center module (COT). CARIN-RDI uses three 64kbps channels out of a 2Mbps link to transfer various data and O&M information based on HDLC protocol.

CARIN-RDI provides lets

• Four RS-232 ports
• Two attendant console ports

» Specifications

Parameters Descriptions
E1 Interface Line Code HDB3
Line Rate 2.048Mbit/s
Line Impedance Unbalanced 75 Ohm
Jitter Tolerance CCITT G.824
Data Channel Three Channel Selectable 1-3 or 29-31
Compliance CAS, PRI, V5.1, V5.2, CCS7
Synchronization Master / Slave / Free-run Selectable
Connector Local & Network 75 Ohm Siemens Coax cable
Serial Srial Port Four Port RS232
Baud Rate 2400bps / 4800bps / 9600bps Selectable
Connector DB9 Serial RS232 Standard
Attendant Attendant Ports Two Ports
Baud Rate 4800bps
Connector DB15 Carin Attendant Standard
General Display 13 LED Indicator
Maintenance Through RS232 Interface With DB9 Connector
Power Requirement 36 ~ 72Vdc, Max.130mA (6.5W)
Temperature Operating range 0 ~ 60 C
Humidity 5 % ~ 95 %
Dimensions 50(H) x 450(W) x 320(D) mm